Programming Language Visual Studio Versions Supported by NI488. Unmanaged CC 6. 0 12, 2003 2, 2005, 2008, 2010, and 2012. NET Framework 3. 5 Languages. Download Visual Studio 2010 Express ISO image. How and where from to download Visual Studio 2010 Express ISO image or offline installer. Visual Studio 2010 Express Download Offline Installer' title='Visual Studio 2010 Express Download Offline Installer' />NI 4. Windows, Version 1. Readme 2. 01. 4 National Instruments Corporation. All rights reserved. This file contains release notes, patent information, and last minute information for NI 4. Windows, Version 1. Some information in this file may be too recent to be included in the official documentation set. Parts of this document are only relevant to a full installation and do not apply to a runtime only installation. This readme contains the following main sections Release Notes. Physical Address Extensions on Windows Server 2. R2. Support for Windows Server 2. R2 may require disabling physical address extensions PAE. To learn how this might affect your use of Windows Server 2. Info Code PAESupport. Win. 16 and DOS Support. Win. 16 and DOS support are available on 3. Windows operating systems. NI 4. 88. 2. NET Framework Help. When installing on a system that already has a version of. VS%20Installation/3.jpg' alt='Visual Studio 2010 Express Download Offline Installer' title='Visual Studio 2010 Express Download Offline Installer' />NET Framework installed, NI 4. NET Framework Help will appear in the Start menu or on Windows 8 in NI Launcher. This help requires a viewer, available with Visual Studio or other. NET development environments. If you do not have a viewer installed, you will receive a Missing Shortcut error when you try to launch the help. Upgrading from Released NI 4. Versions. This driver allows upgrades starting from NI 4. Visual Studio 2010 Express Download Offline Installer' title='Visual Studio 2010 Express Download Offline Installer' />Windows, Version 2. Windows XP. To install over software lower than Version 2. Windows XP, you must uninstall the lower version first. To uninstall on Windows XP, go to the Control Panel and select AddRemove Programs. Unsupported NI 4. Microsoft Office MS 2010 Free Download. It is an offline installer of MS Office 2010. You can download that for windows 8 and windows 7. Free Download trial version of Visual Studio 2017 Professional ISO setup file. It is Stand alone offline installer of Microsoft Visual Studio 2017 ISO Professional. Should I remove Microsoft Silverlight by Microsoft Microsoft Silverlight is an application framework for writing and running rich Internet applications, with. Filename wdexpressfull. Details Visual Studio Express 2018 full offline installer setup for PC 32bit64bit. R5A6zg7w/hqdefault.jpg' alt='Visual Studio 2010 Express Download Offline Installer' title='Visual Studio 2010 Express Download Offline Installer' />Visual Studio 2010 Express Download Offline InstallerVersions on Windows Vista. NI 4. 88. 2 for Windows, Version 2. Windows Vista. If you installed a version of NI 4. Version 2. 5. 2 on Windows Vista, you must uninstall it. To uninstall on Windows Vista, go to the Control Panel and select Programs and Features. After uninstalling the unsupported driver on Windows Vista, you must run a clean up utility. For this utility and more information, visit ni. BH3. 66. K. Downgrading to Lower NI 4. Versions. You must uninstall a higher version before installing a lower version. Known compatibility issues with Windows 8 NI 4. Fast Startup introduced in Windows 8. Leaving Fast Startup enabled may cause improper functioning of the NI 4. GPIB hardware. To prevent problems with installing or removing hardware, National Instruments recommends disabling Fast Startup. The NI 4. 88. 2 for Windows, Version 1. Fast Startup by default. For more information about this issue, please visit ni. Info Code Win. 8Fast. Startup. For more information about changes in NI 4. Windows, Version 1. Enhancements and Bug Fixes in Version 1. Supported Interfaces. NI 4. 88. 2 for Windows, Version 1. GPIB communication using the following hardware. GPIB Interface. Windows 8. SP1Vista SP2Server 2. R2Server 2. 00. 8 R2 SP1. Windows XP SP3Server 2. R2 SP2 3. 2 BitAT GPIBTNT Pn. PNo. Yes. GPIB ENET1. Yes. 1Yes. 1GPIB ENET1. Yes. Yes. GPIB USB BYes. Yes. GPIB USB HSYes. Yes. GPIB USB HSYes. Yes. NI Express. Card GPIBYes. Yes. NI PCIe GPIBYes. Yes. NI PCIe GPIBYes. Yes. NI PCI GPIBYes. Yes. NI PCI GPIBYes. Yes. NI PCI GPIBLPYes. Yes. NI PCI 8. 21. Yes. Yes. NI PCI 8. Yes. Yes. NI PCMCIA GPIBNo. Yes. NI PCMCIA GPIBNo. Yes. NI PMC GPIBYes. Yes. NI PXI GPIBYes. Yes. NI PXI 8. 21. Yes. Yes. NI PXI 8. Yes. Yes. 1The GPIB ENET1. GPIB ENET1. 00. Support for the GPIB ENET1. NI 4. 88. 2 for Windows. The GPIB ENET1. Supported GPIB Analyzer Interfaces. NI 4. 88. 2 for Windows, Version 1. GPIB Analyzer functionality using the following hardware. GPIB Interface. Windows 8. SP1Vista SP2Server 2. R2Server 2. 00. 8 R2 SP1. Windows XP SP3Server 2. R2 SP2 3. 2 BitNI PCIe GPIBYes. Yes. NI PCI GPIBYes. Yes. NI PCMCIA GPIBNo. Yes. GPIB USB HSYes. Video Cutter Software. Yes. Compatible Software. This driver version is recommended for use with the following National Instruments software NI VISA 1. Any version of NI VISA prior to 5. NI 4. 88. 2 usability issues. Upgrade to NI VISA version 5. NI 4. 88. 2 devices. Lab. VIEW 2. 01. 1, 2. Lab. WindowsCVI 2. Measurement Studio 2. Measurement Studio Examples. The Measurement Studio examples install to various directories, depending on the following The component installed. The Visual Studio or. NET Framework version that the example supports. The Measurement Studio version installed. The operating system. For detailed information on examples for Measurement Studio, refer to Where To Find Examples in the NI Measurement Studio Help. Microsoft Visual Studio Support. The following table lists the programming languages and Microsoft Visual Studio versions supported by NI 4. Programming Language. Visual Studio Versions Supported by NI 4. Unmanaged CC6. NET Framework 3. LanguagesC and Visual Basic. NET2. 00. 8. NET Framework 4. LanguagesC and Visual Basic. NET2. 01. 0. NET Framework 4. LanguagesC and Visual Basic. NET2. 01. 23Visual Basic. Programs built in debug mode using Microsoft Visual C 6. For how to solve this problem, go to ni. DNDRI2. F. 2 Microsoft Visual CC 6. GPIB applications. Requires Windows Vista SP2 or later. Visual Basic 6. 0 does not support 6. GPIB applications. NI 4. 88. 2 for Windows, version 2. Visual C MFC 2. Additions made to the NI 4. API after version 2. Visual C MFC support. If you are using. NET Framework 2. 0 and you need NI 4. NI 4. 88. 2 3. 1 or earlier. However, if you installed. NET Framework 2. 0 support from a previous version of NI 4. For more information on NI 4. NET Framework 2. 0, including considerations for users upgrading from NI 4. Info Code 4. 88mvs. If you are using. NET Framework 1. 1 or Visual C MFC 2. NI 4. 88. 2 support, you must use NI 4. However, if you installed. NET Framework 1. 1 or Visual C MFC 2. NI 4. 88. 2, upgrading to version 1. For more information on NI 4. NET Framework 1. 1 or Visual C MFC 2. NI 4. 88. 2 2. 8 or earlier, visit ni. Info Code 4. 88mvs. Borland Support. NI 4. ANSI C support for Borland 5. Enhancements and Bug Fixes in Version 1. New hardware support This release adds support for the GPIB USB HS GPIB controller. Analyzer. Along with this, the NI GPIB Analyzer utility has undergone. The NI GPIB. Analyzer utility allows simultaneous use of multiple GPIB USB HS analyzers. USB GPIB analyzer. Windows Server Support This release adds support for Windows Server 2. R2. Refer to the Supported Interfaces. API integer type changes The integer types used in the NI4. API ni. 48. 82. h have been. All uses of unsigned long have been. These types are. functionally identical with all supported compilers, and this change improves. GPIB applications to other platforms. Users of ibnotify will need to update the function. In most other cases applications will. This change is fully binary compatible with applications built. NI 4. 88. 2 and does not impact users of the GPIB 3. API ni. 48. 8. h. Runtime Installer NI 4. Windows is now available in a smaller. Runtime form. The NI 4. Runtime is a minimal installation which does not. NI 4. 88. 2 distribution. When building installers from Lab. VIEW or other NI. NI 4. 88. 2 in your distribution. The following issues were resolved in NI 4. Attempting to bring a non existent. Ibc. Send. LLO board configuration option causes. ENOL error instead of EBUS. This problem impacted all USB based GPIB. This has been fixed. The EOIP status bit could remain set. EDVR error. 1. 71. An ibnotify callback could fail to be. END if the notify condition included END but not CMPL. Asynchronous transfers could sometimes. EABO even though the transfer completed successfully.